Danger due to insufficiently dimensioned ground conductor.
Damage to the inverter due to thermal overload can result.
1
2
3
CAUTION!
The national standards and guidelines must be observed for dimensioning
the ground conductor.
Loosen the 2 screws on the underside
of the housing cover by rotating them
180° to the left using a screwdriver
(TX20). Then lift the housing cover
away from the inverter at the bottom
and detach from above.
Loosen the 5 screws of the connection
area cover by rotating them 180° to
the left using a screwdriver (TX20).
Remove the connection area cover
from the device.
Press the lock on the back of the ter-
minal and remove the AC terminals.
Loosen the cable gland.
163