Disassembly; Valve Block Disassembly; Disassembling Multi-Blocks; Disassembling Hose Lines - Burkert 8640 Operating Instructions Manual

Modular valve island for pneumatics with width per station 19 mm
Table of Contents

Advertisement

Maintenance, troubleshooting
11

DISASSEMBLY

WARNING!
Risk of injury due to high pressure and escaping medium.
▶ Switch off the pressure before working on the device or system.
Vent or drain the pipes.
Risk of injury due to electric shock.
▶ Switch off voltage before working on the device or system.
Secure against reactivation.
▶ Observe any applicable accident prevention and safety regu-
lations for electrical devices.
WARNING!
Risk of injury due to improper disassembly.
▶ Only trained specialist personnel may carry out the disassembly.
▶ Perform disassembly work using suitable tools only.
Risk of injury from dangerous fluids.
▶ Before loosening lines or valves, flush out hazardous media,
depressurise and drain the lines.
11.1

Valve block disassembly

→ Loosen the clamping screws (approx. 4 turns).
→ Remove the block upwards from the standard rail.
11.2

Disassembling multi-blocks

→ Use the screwdriver to disengage the upper latch hook from
the disassembly groove on the front side.
→ Remove the sub-block/module from the side.
11.3

Disassembling hose lines

→ To release the lines, push in the thrust collar and pull out the
hose line.
Type 5470
12

RIGHT CONNECTION MODULE

Other application options:
• Connection modules on the right can be used in special appli-
cations as sub-modules to build up several operating pressure
stages in one block.
• Makes additional feed possible for larger valve blocks.
NOTE!
If necessary, pierce the lateral predetermined breaking points
of connections 1 and 3.
13
TRANSPORTATION, STORAGE,
DISPOSAL
NOTE!
Damage in transit due to inadequately protected devices.
▶ Protect the device against moisture and dirt in shock-resis-
tant packaging during transportation.
▶ Observe permitted storage temperature.
▶ Protect the electrical interfaces of the coil and the pneumatic
connections from damage by placing protective caps on
them.
Incorrect storage may damage the device.
▶ Store the device in a dry and dust-free location.
▶ Storage temperature: –40...+55 °C.
Damage to the environment caused by device parts contami-
nated with media.
▶ Dispose of the device and packaging in an environmental-
ly-friendly manner.
▶ Observe applicable disposal and environmental regulations.