Pt100 input module

Advertisement

2. SPECIFICATIONS
MELSEC-A
(3)
Count averaging processing times
Data conversion in the channel which is specified for count averaging is
done the number
of times (count) set with
the PC CPU
for
averaging
processing.
Temperature
('C)
Next
average
average
I
I
---+
Time (msec)
When an average value is being calculated, the previous average is
stored in buffer memory.
IRE MARK^
The sampling time (in which sampling is done set number of times) varies with the number
of
channels used.
~~~~1~~~~~~
= (set number of times)
x
(number of channels)
x
(40 mseckhannel)
I
:
are
10, 20,
and
30
times
I
Setting
Number
of
Setting
Times
C H I
10
Sampling Time
10 times
x
3 channels
x
40 msec/channel
=
1200 (msec)
20 times
x
3 channels
x
40 rnsedchannel = 2400 (msec)
30 times
x
3 channels
x
40 rnsedchannel
=
3600 (msec)