Connecting to a
lighting controller
When the expected
voltage is supplied
- When connecting to the illuminator trigger input of a lighting controller,
connect an auxiliary signal capable of sending out a strobe signal. To source the
voltage for the signal, use an external power supply.
If the power supply outputs the voltage expected by the lighting controller,
you need to add an external pull-up resistor. The external resistor pulls the
voltage up to the external power supply's voltage (+V
24V
Aux4
Aux5
Aux6
Aux7
LED+
LED-
GND
Matrox Breakout Box
Direct output connector
Note that if your lighting controller expects a 24 V signal, you can connect
the wire of your external pull-up resistor to the 24 V wire-terminal of the
direct output connector.
Connect the GND wire-terminal of the direct output connector and the
ground of the lighting controller to a common ground.
Note that you must choose an appropriate resistance value for the pull-up
resistor based on the voltage (V) and current (I) that your lighting controller
expects for its trigger input signals. Also, you should choose a resistor rated
at a power higher than the expected peak power. The following formulas can
be used to calculate the required resistance (R) and the expected power for
that resistance (P).
Routing output signals from your Matrox camera
+V
ext
+V
External
pull-up
resistor
+
-
Digital In
GND
Lighting controller
V
V
P
=
-- -
R
=
-- -
R
I
).
ext
Note that +V
ext
cannot exceed 24 V.
+