3.5.1) Double ignition coil - removal
Step
1 Allen screw
2 Washer
3 Cable clamp
Step
m
08 February 2024
Initial Issue
Copyright - BRP-Rotax GmbH & Co KG. All rights reserved.
1
Disconnect the negative terminal of the battery.
2
Remove the cable clamps with Allen screws and lock washers from the intake mani-
fold, if necessary.
3
Cut the cable tie from the exhaust gas temperature sensor cable (cyl. 1_3) connected
with the double ignition coil cable.
Do not damage the cables. Always cut cable ties on the side of the support
NOTICE
plate facing away from the cables.
WARNUNG
SERVICE INSTRUCTION
Procedure
Fig. 2
Procedure
74-20-00
Page 7 of 15