Download Print this page

Rotax 912 i Series Service Instruction page 11

Hide thumbs Also See for 912 i Series:

Advertisement

SI-912 i-029 / SI-915 i-012
SI-916 i-007
Measuring points
Primary side
Secondary side
Between primary
and secondary side
3.5.4) Double ignition coil - installation
Step
1 Protection hose
2 Ignition cable
3 Protective cap
4 Threaded prong
08 February 2024
Initial Issue
Copyright - BRP-Rotax GmbH & Co KG. All rights reserved.
Measurement
Resistance
0.5 Ω +/- 0.5 Ω
9 kΩ +/- 0.9 kΩ
Infinite
See current Maintenance Manual Heavy (MMH) for the respective engine type, Chapter
74-20-00.
1
Screw ignition cable clockwise into coil.
2
Slide rubber seal over coil.
3
Place the appropriately marked protection hose over the ignition cable.
SERVICE INSTRUCTION
Double ignition coil
Procedure
Fig. 8
Figure
74-20-00
Page 11 of 15

Advertisement

loading

This manual is also suitable for:

915 i series916 i series