Step
1 Double ignition coils
2 Ignition coil connector
3.5.2) Wiring harness - removal
3.5.3) Double ignition coil - inspection
Step
08 February 2024
Initial Issue
Copyright - BRP-Rotax GmbH & Co KG. All rights reserved.
7
Unplug the connectors to the double ignition coils. See current Maintenance Manual
Heavy (MMH), Chapter 76-50-00 Wiring harness - removal.
8
Remove the double ignition coils.
See current Maintenance Manual Heavy (MMH) for the respective engine type, Chapter
76-50-00 Wiring harness - removal.
Carry out a visual inspection. See current Maintenance Manual Line (MML) for the re-
spective engine type, Chapter 05-20-00 section Visual inspection.
1
Carry out a visual inspection, check double ignition coils for damage, corrosion, and
deformation
2
Carry out a resistance test. To do this, see current Maintenance Manual Heavy (MMH),
Chapter 76-70-00 section Sensors and actuators.
SERVICE INSTRUCTION
Procedure
Fig. 7
Procedure
74-20-00
Page 10 of 15