Conair TS Series User Manual page 86

Up cut saw
Table of Contents

Advertisement

4 b - 1 6
l O p e r a t i o n
C o n t r o l Pa g e Pa r a m e t e r D e s c r i p t i o n s
( c o n t i n u e d )
Timers From Menu Screen
Start delay:
This data entry field sets the amount of time the saw will dwell after
the saw start pushbutton is pressed, entering automatic. This delay
time allows time for the saw blade to ramp up to the running speed.
Saw raise delay:
This data entry field sets the amount of time the saw will wait for
the clamps to close, after the table reaches line speed and the
clamps have been energized.
Dump table delay:
This data entry field sets the time after the cut cycle is complete and
when the dump table output will turn on.
Dump table duration: This data entry field sets the amount of time the dump table output
will remain on.