4 - 4 b
l O p e r a t i o n
H o w t o N a v i g a t e t h e H M I S c r e e n s
CONTROL PAGES
Mode Select page:
Timers page:
Encoder Setup:
Manual Functions page:
STATUS PAGES
Blade Drive Status
Control Status page:
Input Status page:
Output Status page:
Ethernet page:
This page allows mode selection. The three (3) sources of
demand cutting are: "Encoder", "Timer" and "End Sense".
This page shows data for saw raise delay, table return delay,
dump table delay, and dump table duration.
This page shows data for Encoder scale factor and Encoder
counts. This is set at the factory and should not require further
adjustment.
This page gives the User access to all manual functions of the
TS Up Cut Saw.
This page allows access to the TS Up Cut Saw blade drive sta-
tus. The information displayed on this page would be used to
help troubleshoot problems encountered with the saw operation.
This page allows access to the saw servo control module status.
The information displayed on this page would be used to help
troubleshoot problems encountered with the saw.
This page allows access to the saw servo control digital input
status. The information displayed on this page would be used to
help troubleshoot problems encountered with the saw.
This page allows access to the saw servo control digital output
status. The information displayed on this page would be used to
help troubleshoot problems encountered with the saw.
This page allows access to the Ethernet communication with the
Table drive and Blade drive