Conair TS Series User Manual page 45

Up cut saw
Table of Contents

Advertisement

C o n t r o l Pa g e Pa r a m e t e r D e s c r i p t i o n s
( c o n t i n u e d )
Table Setup
Table run torque limit:
Table jog torque limit:
Cut abort distance:
Table position at cut complete: This display field shows the table position when saw
This data entry field sets the upper torque limit of the
table servo drive when the saw is running in automatic. If
the torque produced by the servo drive exceeds this value
a fault will be generated and automatic will be turned off.
This is set at the factory and should not require further
adjustment.
This data entry field sets the upper torque limit of the
table servo drive when jogging the table in manual. If the
torque produced by the servo drive exceeds this value a
fault will be generated and jogging will stop. This is set
at the factory and should not require further adjustment.
This data entry field sets the table travel distance at which
the cut cycle will be aborted in not already completed. At
this distance the saw blade will be lowered, clamps
opened and table returned.
blade reaches the up proximity sensor.
( C o n t i n u e d )
O p e r a t i o n l
4 a - 2 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts524 upTs724 upTs924 up

Table of Contents