Conair TS Series User Manual page 43

Up cut saw
Table of Contents

Advertisement

C o n t r o l Pa g e Pa r a m e t e r D e s c r i p t i o n s
( c o n t i n u e d )
Table Speeds Encoder Reference
Speed reference select: This button changes the source of the table speed reference. Two
input sources are available, "Encoder" and "Hmi". Pressing this
button will toggle between the two sources. When "Encoder" is
selected, the upstream puller provides the signal or an encoder
mounted to the upstream puller provides the signal.
Sync ratio:
This data entry field sets the synchronization ratio between the
table speed and the speed of the upstream puller. Increase this
value to make the table run faster than the upstream puller.
Decrease this value to make the table run slower than the
upstream puller.
Advance accel:
This data entry field sets the acceleration rate the table uses to
ramp up to line speed.
Advance decel:
This data entry field sets the deceleration rate the table uses to
ramp to a stop after the cut cycle is complete.
Return speed:
This data entry field sets the table return speed, used when the
table returns to the home position after the cut cycle is complete.
Return accel:
This data entry field sets the acceleration rate the table uses to
ramp up to the return speed.
Return decel:
This data entry field sets the deceleration rate the table uses to
ramp to a stop when returning to the home position.