F13:Process Pid Control - Veichi AC310 Series Manual

Frequency ac drive
Hide thumbs Also See for AC310 Series:
Table of Contents

Advertisement

F12.5x: EX-A,EX-B Communication
Parameter
Name
(Address)
Expansion port
F12.50
communication
(0x0C32)
disconnection
processing
F12.51
Expansion port EX-A
(0x0C33)
parameter update
F12.52
Expansion port EX-B
(0x0C34)
parameter update
Expansion port EX-A
F12.53
monitoring frame
(0x0C35)
address group 1
Expansion port EX-A
F12.54
monitoring frame
(0x0C36)
address group 2
Expansion port EX-A
F12.55
monitoring frame
(0x0C37)
address group 3
Expansion port EX-A
F12.56
monitoring frame
(0x0C38)
address group 4
Expansion port EX-B
F12.57
monitoring frame
(0x0C39)
address group 1
Expansion port EX-B
F12.58
monitoring frame
(0x0C3A)
address group 2
Expansion port EX-B
F12.59
monitoring frame
(0x0C3B)
address group 3
Expansion port EX-B
F12.60
monitoring frame
(0x0C3C)
address group 4
4.16 F13:Process PID Control
F13.00-F13.06: PID given and feedback
Parameter
Name
(Address)
F13.00
PID controller given
(0x0D00)
signal source
F13.01
Keyboard digital PID
(0x0D01)
given / feedback
F13.02
PID given change time
(0x0D02)
AC310 Series Frequency AC Drive Manual
6:1Mbps
Content
V/F SVC FVC PMVF PMSVC PMFVC
Unit: EX-A port disconnection action mode
0: No detection 1: Alarm and free stop 2: Warning and continue to
run
Ten digits: EX-B port disconnection action mode
0: No detection 1: Alarm and free stop 2: Warning and continue to
run
V/F SVC FVC PMVF PMSVC PMFVC
0: No update 1: The initial value has been updated after power-on
2: Expansion port EX-A parameter recovery initial value
V/F SVC FVC PMVF PMSVC PMFVC
0: No update 1: The initial value has been updated after power-on
2: Expansion port EX-n parameter recovery initial value
V/F SVC FVC PMVF PMSVC PMFVC
Ten digits: the lower address is 8 digits 00 to 63
Hundreds of thousands: address high 8 bits 00 ~ 07
V/F SVC FVC PMVF PMSVC PMFVC
Ditto
V/F SVC FVC PMVF PMSVC PMFVC
Ditto
V/F SVC FVC PMVF PMSVC PMFVC
Ditto
V/F SVC FVC PMVF PMSVC PMFVC
Ditto
V/F SVC FVC PMVF PMSVC PMFVC
Ditto
V/F SVC FVC PMVF PMSVC PMFVC
Ditto
V/F SVC FVC PMVF PMSVC PMFVC
Ditto
Content
V/F SVC FVC PMVF PMSVC PMFVC
0: Keyboard digital PID given 1: Keyboard analog potentiometer
given
2: Current/voltage analog AI1 given
3: Current/voltage analog AI2 given
4: Reserved 5: Terminal pulse PUL given
6: RS485 communication reference 7: Option card
8: Terminal selection 9: Communication given active current
V/F SVC FVC PMVF PMSVC PMFVC
Set keyboard digital PID given / feedback value
V/F SVC FVC PMVF PMSVC PMFVC
Set the PID given change time
39
Factory default
Adjustable
(range)
properly
0000
RUN
(0000~0022)
0
RUN
(0 ~ 2)
0
RUN
(0 ~ 2)
0001
RUN
(0000 ~ 0763)
0002
RUN
(0000 ~ 0763)
0007
RUN
(0000 ~ 0763)
0011
RUN
(0000 ~ 0763)
0001
RUN
(0000 ~ 0763)
0002
RUN
(0000 ~ 0763)
0007
RUN
(0000 ~ 0763)
0011
RUN
(0000 ~ 0763)
Factory default
Adjustable
(range)
properly
0
RUN
(0 ~ 9)
50.0%
RUN
(0.00~100.0%)
1.00s
RUN
(0.00~60.00s)