F06.30
Relay 1 output OFF
(0x061E)
delay time
F06.31
Extended Y1 output
(0x061F)
OFF delay time
F06.32
Extended relay 2
(0x0620)
output OFF delay time
Frequency Detection
F06.4x:
Parameter
Name
(Address)
F06.40
Frequency detection
(0x0628)
value 1
F06.41
Frequency detection
(0x0629)
amplitude 1
F06.42
Frequency detection
(0x062A)
value 2
F06.43
Frequency detection
(0x062B)
range 2
The given frequency
F06.44
reaches the detection
(0x062C)
range
F06.5x:Monitor parameter comparator output
Parameter
Name
(Address)
F06.50
Comparator 1 monitor
(0x0632)
selection
F06.51
Comparator 1 upper
(0x0633)
limit
F06.52
Comparator 1 lower
(0x0634)
limit
F06.53
Comparator 1 bias
(0x0635)
F06.54
Action selection when
(0x0636)
sending CP1
F06.55
Comparator 2 monitor
(0x0637)
selection
F06.56
Comparator 2 upper
(0x0638)
limit
F06.57
Comparator 2 lower
(0x0639)
limit
F06.58
Comparator 2 bias
(0x063A)
F06.59
Action selection when
(0x063B)
sending CP2
F06.6x:Virtual Input and Output Terminal
AC310 Series Frequency AC Drive Manual
V/F SVC FVC PMVF PMSVC PMFVC
Set relay 1 output OFF delay time.
V/F SVC FVC PMVF PMSVC PMFVC
Set the extended Y1 output OFF delay time
V/F SVC FVC PMVF PMSVC PMFVC
Set the extended relay 2 output OFF delay time.
Content
V/F SVC FVC PMVF PMSVC PMFVC
Set the frequency detection value 1
V/F SVC FVC PMVF PMSVC PMFVC
Set the frequency detection amplitude 1
V/F SVC FVC PMVF PMSVC PMFVC
Set the frequency detection value 2
V/F SVC FVC PMVF PMSVC PMFVC
Set the frequency detection range 2
V/F SVC FVC PMVF PMSVC PMFVC
Set the given frequency to reach the detection range
Content
V/F SVC FVC PMVF PMSVC PMFVC
Units and Tens digits: Set yy value of the Cxx.yy 00~63
Hundreds and thousands: Set xx value of the Cxx.yy 00~07
V/F SVC FVC PMVF PMSVC PMFVC
Set the upper limit of comparator 1
V/F SVC FVC PMVF PMSVC PMFVC
Set the lower limit of comparator 1
V/F SVC FVC PMVF PMSVC PMFVC
Set the comparator 1 offset value
V/F SVC FVC PMVF PMSVC PMFVC
0:Continue running(digital terminal output only);
1:Warning and free stop;2:Warning and continue running;
3:Forced stop
V/F SVC FVC PMVF PMSVC PMFVC
Units and Tens digits: Set yy value of the Cxx.yy 00~63
Hundreds and thousands: Set xx value of the Cxx.yy 00~07
V/F SVC FVC PMVF PMSVC PMFVC
Set the upper limit of comparator 2
V/F SVC FVC PMVF PMSVC PMFVC
Set the lower limit of comparator 2
V/F SVC FVC PMVF PMSVC PMFVC
Set the comparator 2 offset value
V/F SVC FVC PMVF PMSVC PMFVC
0: Continue running (digital terminal output only)
1: Warning and free stop 2: Warning and continue to run 3: Forced
stop
27
0.010s
RUN
(0.000~60.000s)
0.010s
RUN
(0.000~60.000s)
0.010s
RUN
(0.000~60.000s)
Factory default
Adjustable
(range)
properly
2.00Hz
(0.00~max
RUN
frequency)
1.00Hz
(0.00~max
RUN
frequency)
2.00Hz
(0.00~max
RUN
frequency)
1.00Hz
(0.00~max
RUN
frequency)
2.00Hz
(0.00~max
RUN
frequency)
Factory default
Adjustable
(range)
properly
0001
RUN
(0000 ~ 0763)
3000
RUN
(0 ~ 65535)
0
RUN
(0 ~ 65535)
0
RUN
(0 ~ 1000)
0
RUN
(0 ~ 3)
0002
RUN
(0000 ~ 0763)
30
RUN
(0 ~ 65535)
0
RUN
(0 ~ 65535)
0
RUN
(0 ~ 1000)
0
RUN
(0 ~ 3)