F13.25-F13.28: PID Feedback Disconnection judgment
Parameter
Name
(Address)
Feedback
F13.25
disconnection action
(0x0D19)
selection
Feedback
F13.26
disconnection
(0x0D1A)
detection time
F13.27
Wire break alarm
(0x0D1B)
upper limit
F13.28
Wire break alarm lower
(0x0D1C)
limit
F13.29-F13.33: PID Sleeping Function
Parameter
Name
(Address)
F13.29
Sleep selection
(0x0D1D)
F13.30
Sleep frequency
(0x0D1E)
F13.31
Sleep delay
(0x0D1F)
F13.32
Wake up deviation
(0x0D20)
F13.33
Wake-up delay
(0x0D21)

4.17 F14:Multi-speed and Simple PLC

F14.00~F14.14:Multi-speed given
Parameter
Name
(Address)
F14.00
Multi-speed 1
(0x0E00)
F14.01
Multi-speed 2
(0x0E01)
F14.02
Multi-speed 3
(0x0E02)
F14.03
Multi-speed 4
(0x0E03)
F14.04
Multi-speed 5
(0x0E04)
F14.05
Multi-speed 6
(0x0E05)
F14.06
Multi-speed 7
(0x0E06)
AC310 Series Frequency AC Drive Manual
Content
V/F SVC FVC PMVF PMSVC PMFVC
V/F SVC FVC PMVF PMSVC PMFVC
0: Continue PID operation without reporting fault 1: Stop and report
fault
2: Continue PID operation and output alarm signal
3: Run at the current frequency, output alarm signal
V/F SVC FVC PMVF PMSVC PMFVC
Set feedback disconnection detection time
V/F SVC FVC PMVF PMSVC PMFVC
Set the upper limit of the disconnection alarm
V/F SVC FVC PMVF PMSVC PMFVC
Set the upper limit of the disconnection alarm
Content
V/F SVC FVC PMVF PMSVC PMFVC
Set whether sleep is effective
0: off 1: valid
V/F SVC FVC PMVF PMSVC PMFVC
Set sleep frequency
V/F SVC FVC PMVF PMSVC PMFVC
Set the time of sleep delay
V/F SVC FVC PMVF PMSVC PMFVC
Set wakeup deviation
V/F SVC FVC PMVF PMSVC PMFVC
Set wakeup delay
Content
V/F SVC FVC PMVF PMSVC PMFVC
Set PLC multi-speed 1
V/F SVC FVC PMVF PMSVC PMFVC
Set PLC multi-speed 2
V/F SVC FVC PMVF PMSVC PMFVC
Set PLC multi-speed 3
V/F SVC FVC PMVF PMSVC PMFVC
Set PLC multi-speed 4
V/F SVC FVC PMVF PMSVC PMFVC
Set PLC multi-speed 5
V/F SVC FVC PMVF PMSVC PMFVC
Set PLC multi-speed 6
V/F SVC FVC PMVF PMSVC PMFVC
Set PLC multi-speed 7
41
Factory default
Adjustable
(range)
properly
0
STOP
(0 ~ 3)
1.0s
RUN
(0.0~120.0s)
100.0
RUN
(0.0~100.0%)
0.0%
RUN
(0.0~100.0%)
Factory default
Adjustable
(range)
properly
0
RUN
(0 ~ 1)
10.00Hz
(0.00~Max
RUN
frequency)
60.0S
RUN
(0.0~3600.0S)
5.0%
RUN
(0.0~50.0%)
1.0S
RUN
(0.0~60.0S)
Factory default
Adjustable
(range)
properly
10.00Hz
(0.00~Max
RUN
frequency)
20.00Hz
(0.00~ Max
RUN
frequency)
30.00Hz
(0.00~ Max
RUN
frequency)
40.00Hz
(0.00~Max
RUN
frequency)
50.00Hz
(0.00~ Max
RUN
frequency)
40.00Hz
(0.00~ Max
RUN
frequency)
30.00Hz
(0.00~ Max
RUN
frequency)