4.4 F01:Basic Settings
F01.0x:Basic command
Parameter
Name
(Address)
F01.00
Motor control
(0x0100)
F01.01
Run command
(0x0101)
channel
F01.02
Frequency given
(0x0102)
channel A
AC310 Series Frequency AC Drive Manual
Content
V/F SVC FVC PMVF PMSVC PMFVC
Set the parameter access level based on the case of restricted
parameter access.
0: standard parameter (Fxx.yy)
1: Common parameters (F00.00, Pxx.yy)
2: Monitoring parameters (F00.00, Cxx.yy)
3: Changed parameter(F00.00, Hxx.yy)
V/F SVC FVC PMVF PMSVC PMFVC
Set the AC Drive initialization method.
0: not initialized
11: Select the set value according to the purpose to perform the
parameter (excluding the motor parameter)
22: All parameters are initialized
33: Clear the fault record
V/F SVC FVC PMVF PMSVC PMFVC
0: no function
1: Upload parameters to the keyboard
2: Download parameters to the AC Drive
V/F SVC FVC PMVF PMSVC PMFVC
Used to set the user password.
V/F SVC FVC PMVF PMSVC PMFVC
Select the language displayed on the LCD operator.
0: Chinese 1: English
V/F SVC FVC PMVF PMSVC PMFVC
When using multiple machines, use the machine number or usage
mode number.
V/F SVC FVC PMVF PMSVC PMFVC
When using multiple machines, use the machine number or usage
mode number.
V/F SVC FVC PMVF PMSVC PMFVC
"0~00" digits: yy setting in function parameter number Fxx.yy
00~99
"000~0000"digits: xx setting in function parameter number Fxx.yy
00~31
Content
V/F SVC FVC PMVF PMSVC PMFVC
The control mode of the motor.
Asynchronous motor control mode:
0: AM-VF; VF control
1:AM-SVC; open loop vector control, current closed loop control
2: AM-FVC; closed loop vector control
Synchronous motor control mode:
10: PM-VF; VF control
11: PM-SVC; open loop vector control
12: PM-FVC; closed loop vector control
V/F SVC FVC PMVF PMSVC PMFVC
Used to select the channel that the drive accepts the run and stop
commands and the direction of travel.
0: keyboard control (external keyboard priority) 1: terminal control
2: RS485 communication control 3: Option card
V/F SVC FVC PMVF PMSVC PMFVC
The given source channel B of the frequency converter
0: keyboard digital reference frequency 1: keyboard analog
potentiometer given
2: Current/voltage analog AI1 given
3: Current/voltage analog AI2 given
13
Factory default
Adjustable
(range)
properly
0
RUN
(0 ~ 3)
0
STOP
(0 ~ 33)
0
STOP
(0 ~ 9999)
0
STOP
(0 ~ 65355)
0
RUN
(0 ~ 1)
0
RUN
(0 ~ 65535)
0
RUN
(0 ~ 65535)
0102
RUN
(0000 ~ 3199)
Factory default
Adjustable
(range)
properly
0
STOP
(0 ~ 12)
0
RUN
(0 ~ 3)
0
RUN
(0 ~ 11)

Advertisement

Table of Contents
loading

Table of Contents