The table below lists wiring configuration of Power to the Base board of the LWD.

Table 2: Wiring Configuration of Power to the Base Board of the LWD

Power
24V
REF
To connect the CAN network, connect the CANH and CANL as follows:
• If the LWD is in the machine room, connect the network to AN+ and AN-.
• If the LWD is located on the Cartop, connect the network to C3H and C3L.
Each sensor had to be tested individually to verify the sensors has been correctly installed. See
Adjustments steps 1-12.

LEDs

The LEDs display the status of the LWD.
The table below lists LED Indicators.
LED
O1 (Green)
O2 (Green)
O3 (Red)
O4 (Orange)
O5 (Green)
September 29,2021

Figure 4: LED Location

Table 3: LED Indicators

Indicator
Power LED
Heartbeat
Fault
N/A
Serial Comm.
©2021 Smartrise Engineering, Inc. All Rights Reserved
Load Weighing Device
LWD Base Board Connector
Pin 1
Pin 2
Normal Status
On
Blinks 1Hz
Off (On indicates a fault)
Off
Blinks to reflect data traffic from
the C4 controller