Motor; Asynchronous Three-Phase Or Inverter Motor Technical Details - Electrolux 599 76 86-51 Service Manual

Condensation tumble dryer with heat pump and steam generator
Table of Contents

Advertisement

4.15 Motor

The asynchronous three-phase motor used in this tumble dryer has permanent magnets and is driven
directly by the main board.
1
Fan
2
Belt tensioner
3
Motor
4
Vibration damping bushes
The motor unit consists of a belt tensioner (2) situated on an axis on the motor casing and secured by a
spring ring, with one fan (1) for the circulation of hot air, bolted to the motor shaft, of the motor (3) with
thermal cut-out and two vibration damping bushes (4) positioned on the two motor casings. The motor power
connector is located on a shaft fixed to a casing.
Calmed
2
4
4.15.1
Asynchronous three-phase or Inverter motor technical
details
Power supply voltage
Frequency
RPM
Coil resistance 1 - 2
Coil resistance 1 - 3
Coil resistance 2 - 3
Technical Support - A.D.L.
3
4
230V
50 Hz
2700
20.4Ω ± 7% at 20°C
20.4Ω ± 7% at 20°C
20.4Ω ± 7% at 20°C
25/69
2
4
3
1
4
1
Yellow-green
Blue
Red
White
599 76 86-51 Rev. 01