E51
Motor power triac short-circuited
E52
Motor thermal cut-out triggered.
E53
Motor TRIAC "sensing" circuit faulty
E54
Motor blocked.
E55
Inverter board safety alarm
Inverter is drawing too much current
E57
(>15A)
Inverter is drawing too much current
E58
(>4.5A)
No signal from tachometric generator
E59
for 3 seconds
Technical Support - A.D.L.
Full name
The cycle is suspended.
If it is detected before the cycle starts, the cycle
start will not be permitted.
The cycle is suspended.
If it is detected before the cycle starts, the cycle
start will not be permitted.
The cycle is suspended.
If it is detected before the cycle starts, the cycle
start will not be permitted.
The cycle is suspended.
If it is detected before the cycle starts, the cycle
start will not be permitted.
The cycle is suspended.
If it is detected before the cycle starts, the cycle
start will not be permitted.
The cycle is suspended
If it is detected before the cycle starts, the cycle
start will not be permitted.
The cycle is suspended
If it is detected before the cycle starts, the cycle
start will not be permitted.
The cycle is suspended
If it is detected before the cycle starts, the cycle
start will not be permitted.
Action
55/69
Notes and possible causes
Motor faulty.
Faulty wiring.
Main circuit board faulty.
Motor faulty.
Motor thermal cut-out has triggered.
Faulty wiring.
Main circuit board faulty.
Main circuit board faulty.
Washing load is too large.
Power supply voltage low.
Motor/drive system blocked.
----------------
Motor-inverter wiring faulty.
Inverter board faulty.
Motor faulty.
Abnormal motor operation (overload).
Motor-inverter wiring faulty.
Motor faulty.
Inverter board faulty.
Motor-inverter wiring faulty.
Inverter board faulty.
Motor faulty.
599 76 86-51 Rev. 01