Electrolux 599 76 86-51 Service Manual page 28

Condensation tumble dryer with heat pump and steam generator
Table of Contents

Advertisement

Position 3
Counter Clockwise drum rotation
Position 4
Compressor cooling fan and
Steam generator
Position 5
Clockwise drum rotation
Position 6
Compressor and clockwise drum
rotation
Technical Support - A.D.L.
Purpose of the test:
Components activated:
Behaviour:
Working conditions:
Purpose of the test:
Components activated:
Behaviour:
Working conditions:
Purpose of the test:
Components activated:
Behaviour:
Working conditions:
Purpose of the test:
Components activated:
Behaviour:
Working conditions:
28/69
to test the drum rotation motor in an anti-
clockwise direction.
motor TRIAC.
Anti-clockwise direction relay.
Drum rotation motor.
Condensation water filling pump.
The motor turns the drum anti-clockwise and the
condensation water filling pump is in operation.
door closed (timeout 10 mins.).
Test operation of the compressor cooling fan.
Compressor cooling fan TRIAC.
Safety relay.
Steam generator heating element and pump
LCD indicates the temperature read by the NTC
found in the steam generator unit.
Water inside the steam generator tank
otherwise the no water icon flashes.
door closed (timeout 10 mins.).
To test clockwise rotation of the drum.
clockwise drum rotation motor.
Safety relay.
LCD indicates the position of the selector.
the drying temperature NTC1 is displayed on the
LCD.
door closed (timeout 10 secs.).
To test compressor operation.
Compressor.
clockwise drum rotation motor.
LCD indicates the position of the selector.
the drying temperature NTC1 is displayed on the
LCD
door closed (timeout 10 secs.).
599 76 86-51 Rev. 01

Advertisement

Table of Contents
loading