Download Print this page

Installation - Schlage XE360-EW Series Installation Instructions Manual

Advertisement

Installation

1
Prepare door.
Use the included door template to complete the door
preparation.
Do not drill through the backplate. The drill can catch on the
backplate and cause injury.
2
Install DPS (door position switch), if desired.
2a Prepare a 3/ 4" (19 mm) hole, 1 1/2" (38 mm) deep in the jamb
exactly opposite the prepared hole in the door edge.
2b Install the jamb side of the switch into the hole.
Magnet with no wire
2c Route the cable through the hole in the door edge and then
through the hole on the inside of the door. Then push the
switch into the hole.
The location of the DPS wire routing hole varies depending on
which model of exit device you are using. Consult the door
preparation template for exact location.
CAUTION
Route through hole
marked on template.
NOTICE
3
Install exterior assembly.
3a Select correct tailpiece hole and/or length.
Falcon 25R
2 1/2" (64 mm) - 2 3/ 4" (70 mm) door thickness
Falcon 25S
2 1/8" (55 mm) - 2 1/ 4" (57 mm) door thickness
2 1/2" (64 mm) - 2 3/ 4" (70 mm) door thickness
Von Duprin 99R/22R
1 3/ 4" (44 mm) - 2" (51 mm)
door thickness
2 1/8" (55 mm) - 2 1/ 4" (57 mm)
door thickness
Von Duprin 99R/99S/99C/22R/22S
Door
thickness
1 3/ 4" (44 mm)
1 7/8" (48 mm)
2" (51 mm)
2 1/8" (54 mm)
2
1 3/ 4" (44 mm) - 2 1/8" (54 mm)
door thickness
2 1/ 4" (57 mm) door thickness
Trim to 1 15/16" (50 mm)
1 3/ 4" (44 mm) - 2" (51 mm) door thickness
Trim to 2 13/32" (61 mm)
1 3/ 4" (44 mm) - 2" (51 mm)
door thickness
2 1/8" (55 mm) - 2 1/ 4" (57 mm)
door thickness
Trim to
Door
length
thickness
1 3/8"
2 1/ 4" (57 mm)
(35 mm)
2 3/8" (60 mm)
1 5/8"
2 5/8" (67 mm)
(41 mm)
2 3/ 4" (70 mm)
BAG 1
Trim to
length
2 1/8"
(54 mm)
2 3/8"
(60 mm)

Advertisement

loading