D-Series Electrified Locks
D80PDEL, D80PDEU

Installation Instructions

Electrically Locked (Fail Safe): Auxiliary latch deadlocks latchbolt when door is closed. Outside knob or
lever continually locked electrically until unlocked by key, switch, or power failure. Inside knob or lever
always free for immediate exit.
Electrically Unlocked (Fail Secure): Auxiliary latch deadlocks latchbolt when door is closed. Outside knob
or lever continually locked until unlocked by key or electrical current. Inside knob or lever always free for
immediate exit.
Electrical Requirements
• Amps .15; Volts 24 AC
• Amps .35; Volts 24 DC
• Operating Temperature: Maximum +151°F, Minimum -31°F
D-Series Typical Installation
• Provision must be made to route low voltage wires to the lock.
Attach wires to 6" pigtail of rectifier (for AC operation) or solenoid
(for DC operation).
• Power transfer unit and low voltage wiring are not furnished.
• All power requirements shown are for single lock operation. For
multi-lock installations, powered by a single supply, current values
must be increased accordingly.
• Select proper wire size to minimize voltage drop. Voltage
requirements indicated must be maintained at lock for dependable
operation.
Replacement Kit
38-064 – Solenoid and Rectifier, EL (AC and DC)
38-065 – Solenoid and Rectifier, EU (AC and DC)
Note: Spacer furnished with replacement kits to be placed between
solenoid and knob catch on knob designs only.
See reverse side for L-Series Electrified and Request-to-Exit Locks and Electric Latch Release
Typical Wiring Diagram for Electrified D-Series Locks
AC Power Source – EL or EU
Rectifier
Plug
Rectifier used on AC operation unit only
DC Power Source – EL or EU
DC Operation
.35A @ 24V (Current requirements per lock)
AC and DC Application
Solenoid
A
LL INSTALLATIONS SHOULD BE IN ACCORDANCE
WITH LOCAL ELECTRICAL CODES AND
N
E
C
, NFPA 70
ATIONAL
LECTRICAL
ODE
D80PDEL
Switch
Transformer
(Not Furnished)
(Not Furnished)
To Lock
24VAC
Switch
(Not Furnished)
To Lock
Cut as close to plug as
possible for DC operation.
Rectifier
Plug into solenoid for
AC operation. Discard
for DC operation.
©2012 Ingersoll Rand
Printed in U.S.A.
P513-541 Rev. 03/12-d
D80PDEU
115VAC
24V DC