Download Print this page

Installation - Schlage XE360-T Series Installation Instructions Manual

Tubular lock

Advertisement

Installation

1
Prepare door.
Use the included door template to complete the door
preparation.
Do not drill through the backplate. The drill can catch on the
backplate and cause injury.
2
Install DPS (door position switch), if desired.
2a Prepare a 3/ 4" (19 mm) hole, 1 1/2" (38 mm) deep in the jamb
exactly opposite the prepared hole in the door edge.
2b Install the jamb side of the switch into the hole.
Magnet with no wire.
2c Route the cable through the hole in the door edge and then
through the hole on the inside of the door. Then push the
switch into the hole.
3
Install strike.
CAUTION
Route through hole
marked on template.
Actual size
4
Install latch.
4a Adjust latch, if necessary.
Latch is factory set to 2 3/8"
(60 mm) backset.
2 3/8" (60 mm)
4b Install backplate.
Notch
4c Insert the latch into the door edge.
BAG 1
If the latch will not go all the
way into the hole, the latch
needs to be adjusted to the
2 3/8" backset.
Must be flush
with door edge.
See step 4a for adjustment.
2
To change to 2 3/ 4" (70 mm)
backset, pull the back of
latch away from the front.
2 3/ 4" (70 mm)
CAUTION
Faceplate and backplate must be
installed correctly to maintain UL rating
of UL certified locks.
This backplate is
backward.
If the latch does not extend all
the way to the back of the
hole, it needs to be adjusted to
the 2 3/ 4" backset.
Must extend to
back.
BAG 1

Advertisement

loading