Cascading
Mode
SmartLogger
SUN2000-(3KTL-10K
TL)-M1 (with
batteries)
SmartLogger
SUN2000-(3KTL-10K
TL)-M1 (with
batteries)
Table 4-10 Mapping relationship (single-phase)
Cascadin
g Mode
SmartLog
L1
ger
In the off-grid state, the output phases of cascaded inverters are different. The
load outputs of the Backup Boxes connected to each inverters cannot be
connected in parallel. As shown in the following figure, the P-1 output is
connected to primary O-1 and the P-2 output is connected to O-2. The P-1 and
P-2 load outputs cannot be connected in parallel.
Smart Dongle Networking
A maximum of three inverters can be cascaded in the grid-tied and off-grid ESS.
The batteries, power meter, Smart Dongle, and Backup Box need to be connected
to the same inverter.
Issue 15 (2024-01-12)
SUN2000-(3KTL-10KTL)-
M1 (with batteries)
SUN2000-(3KTL-10KTL)-
M1 (with batteries)
L1
NO TE
The grid-tied and off-grid ESS supports a maximum of three SUN2000-(2KTL-6KTL)-L1
inverters (with batteries) cascaded. In this scenario, the inverters can be connected to the
grid only at the same phase and controlled only by a single-phase power meter. Grid
connection at different phases or using a three-phase power meter is not supported.
NO TE
The parameters of each battery need to be set separately. When the grid charging function
is enabled, the surplus power generated by one inverter can be used to charge the other
inverter.
WARNING
Copyright © Huawei Digital Power Technologies Co., Ltd.
4 Application Scenarios and Settings
SUN2000-(8KTL-20KTL)-M2
SUN2000-(3KTL-10KTL)-M1
(with batteries)
L1
52