2.8  Powering Up the Unit
CLI Hot Swap Monitoring
Functionality and status of the Hot Swap Power Supplies can also be obtained by using the
CLI command HS_GetStatus.
This command will return the overall Hot Swap status and total current, as well as the
status and details for each of the bays (health status, present, power type, fan speed,
temp, voltage, current, percentage).
Front Panel Hot Swap Monitoring
If your unit is configured with hot swappable power supplies, an additional menu will be vis-
ible on the front panel OLED information menu.
28
(A)
Current
(RPM)
Fan Speed
(C°)
Temperature
Press the
Menu button (you will need to pres twice if the first press was
Power
waking up the display on the front panel).
Press the right button to highlight the Hot Swap sub-menu:
Press the down button to toggle between specific information for Bay 1 and Bay 2:
In the case of faulty power supplies, the front panel will flash on the important para-
meter(s) to indicate the need for attention (in the image above, the issue on Bay 2 is
with the fan speed and voltage).
You can also disable monitoring on a specific bay by pressing the
while the bay is highlighted. Bays with disabled monitoring will be noted on the front
panel: