SecureSync 2400 Getting Started Guide Rev. 4
In this panel, you can also download (or clear) a file of the most recent monitoring
information for both bays.
The Rear View panel of the Hot Swap page will display a rendering of the rear
panel. You can hover over a power supply to confirm the bay number, and power
specifications.
The Hot Swap Status panels for Bay 1 and Bay 2 each provide information and
charts related to monitoring the power supplies of the unit, and contain the following
elements:
Health: OK, Warning, Fault, or Monitoring Disabled
Present: Installed or Not Installed
Monitoring: ON/OFF. Monitoring of Hot Swap Power Supply statuses can be
disabled to reduce logging and health status updates. This setting disables
alarming in the case of power supply failure or issue (it is still possible to view
statistics for the bay if monitoring is disabled).
Note:
choose to remove a power supply long term or keep one inser-
ted that you know is faulty. Disabling monitoring on a faulty sup-
ply or empty bay will cause the overall status to display as Okay
(provided there is one fully functional power supply installed).
Type: AC 110/220 V, DC 12/24 V, or DC 24/48 V
Power
(V)
Voltage
It is recommended to disable monitoring on a bay if you
2.8  Powering Up the Unit
27