2.5  Mounting the Unit
To rack mount the SecureSync unit:
1.
2. Secure the rack mount brackets to the rack using the #10-32 rack mount screws and
3.
22
Attach the 2400-1000-0714 rack mount ears to the sides of the SecureSync with
the ears facing outward, aligned with the front edge of the SecureSync front panel.
(See image below). To secure, use the #2 Phillips screwdriver, and 3 each of the
HM20R-04R7-0010 M4 flat head Phillips screws per side.
Figure 2-1:
Rack mount installation
#2 Phillips head screwdriver, 2 each per side of the rack.
If you purchased additional rear rack mounts, you will align the holes with the avail-
able pegs near the rear of the unit and slide the rail forward into place.
Secure the mount with the screw hole closest to the front of the chassis using 1 each
of the supplied HM20R-04R7-0010 screws per side.