Step 8: Plug in and connect
the Branch current
transformers
If the Inhab Energy has Branch CTs, open the clasps on the CTs and place each clamp
around the non-neutral leg from the breaker that is to be monitored. Then shut the
clasps to secure the CTs. Then, insert the screw terminal plugs into the ports on the
top of the energy monitor. Note the port numbers. To avoid clutter, unscrew the 22
AWG wires from the screw terminals, cut them to size, and reattach them ensuring the
black and white wires match the icons on the top of the Inhab Energy.
Hazardous Voltage
Will cause death or serious injury.
Turn off and lock out all power supplying this device before working on
this device. Replace all covers before power supplying this device is
turned on.
DANGER
INHAB™ ENERGY INSTALLATION GUIDE