Step 7: Connect the wire harness
The wire harness is wired to one or more breakers in the electric panel.
1.
Wiring to an empty breaker
If wiring to an empty (unused) breaker, wire it directly to the breaker.
Ampacity rating of this breaker does not matter.
2.
Wiring to an in-use breaker
If wiring to an in-use breaker, use the splicing wires / wire nuts included with
the Inhab Energy for breakers rated up to 15A. Any ampacity rating may be
used if the splicing wire guage matches the existing wire and meets applicable
electric codes.
3.
Wiring to a AFCI / GFCI breaker
If the wire harness is connected to an AFCI / GFCI breaker, the black wire
needs to be wired to the hot side and the white to the neutral on this
breaker. The white is not wired to the neutral bus.
Hazardous Voltage
Will cause death or serious injury.
Turn off and lock out all power supplying this device before working on
this device. Replace all covers before power supplying this device is
turned on.