3.9 ROOM THERMOSTAT CONNECTION

An electric terminal is left outside the control panel plastic box so that the control panel
is not opened while connecting an optional room thermostat. You can see this terminal
in the below picture. Remove the jumper cable and connect the room thermostat volt
free cables. When the room thermostat is connected to your boiler;
shown on the LCD screen when the boiler operation is stopped by a signal from the
room thermostat or in case of a room thermostat failure.
WARNING!
&
• Do not connect any voltage to this therminal as this will damage the boiler and
invalidate the warranty.
• In cases where a wireless room thermostat requires a line (220V) connection, a
seperate electricty cable must be connected to the thermostat. Do not make a
connection from the boiler's electricty supply. This may damage the boiler and
invalidate the warranty.

3.10 ELECTRICITY CONNECTION PARAMETERS

Heating Power
Electric Connection Cable 1 Phase
Electric Connection Cable 3 Phase
RCD 1 Phase
RCD 3 Phase
Main Breaker 1 Phase
Main Breaker 3 Phase
Electric Isolation Degree
Heating Power
Electric Connection Cable 1 Phase
Electric Connection Cable 3 Phase
RCD 1 Phase
RCD 3 Phase
Main Breaker 1 Phase
Main Breaker 3 Phase
Electric Isolation Degree
kW
6
pcs./mm2
2 x 6
...
pcs./mm2
A/mA
40 / 30
...
A/mA
A
40
A
25
IP
X4D
kW
30-32-35-40
...
pcs./mm2
pcs./mm2
4 x 10
...
A/mA
A/mA
63 / 30
...
A
A
63
IP
X4D
28
icon will be
Room thermostat icon
10-12
15
...
2 x 10
4 x 4
4 x 4
...
63 / 30
25 / 30
25 / 30
...
63
25
25
X4D
X4D
50
60
80
...
...
...
3x25+16
4x16
4x16
...
...
...
x2 63/30
80/30
100/30
...
...
...
125
80
100
X4D
X4D
X4D
18-24
...
4 x 6
...
40 / 30
...
40
X4D
100
...
3x35+16
...
x2 80/30
...
160
X4D