CONTENT 1. GENERAL WARNINGS BEFORE OPERATING THE UNIT..........Page 4 2. FEATURES OF THE BOILER....................Page 5 3. SECTIONS OF THE BOILER....................Page 6 4. INSTALLATION........................Page 7 4.1 INSTALLATION AND WATER FLOOD................Page 9 BOILER INSTALLATION SCHEMA..................Page 10 4.2 AIR CONNECTION......................
Page 3
PREFACE MAKTEK is one the leading institutions in Turkey in heating industry since its foundation in 1977.Inconsideration of monitoring technological developments closely, MAKTEK takes the pride of presenting MAKTEK Solid Fuel Boilers in Turkey and World market. Our company, which has acquired advanced technology and superior quality, stands on in accordance with these principles.
1.GENERAL WARNING BEFORE OPERATING THE UNIT Please check the conformity of waste gas , water and electric infrastucture of the area to the necessary technical parameters where the boiler will be installed. For safe use of electricity , make sure that the grounding of the installation is isolated and there is no phase.
FEATURES OF THE BOILER Capacity between 25.000 kcal-250.000 kcal/h Burns the fuel which is up to 20mm diameter with high energy thanks to automatic fuel feeding. Heating with high efiiciency for coal and all solid fuels Opportunity for watching and setting the temperature of heating water on digital screen ...
Boiler must be placed where has enough air for an efificient burning. It is required to use open expansion tank in installation MAKTEK MKK-S series boilers. Boiler- expansion tank return pipes must be absolutely isolated in extreme cold regions.
4.1 INSTALLATION AND WATER FLOOD Please use open expansion tank for MAKTEK Solid Fuel Boilers. Closed expansion tank systems may trigger steaming of the boiler when there is an electric cut out or when the pump is not functioning. Please connect open expansion tanks according to standarts.
4.2 AIR CONNECTION The area where the boiler is installed must always be suppplied with fresh air by using a window or a duct. In order for a boiler to burn safely and efficiently, fresh air is required. Otherwise once the burning starts, the oxygen level will drop causing the burning to be inefficient.
There should be no sectional narrow down in any place of the chimney. Main walls of the building should never be used as chimney wall element. The chimney must be inside the building, if the chimney must pass from outside, the isolation must be done properly. The chimney must be frequently cleaned in order to avoid tar and soot and clogs.
Page 14
6. BOILER WITH STOCKER CONTROL PANEL Fuel waiting time Fuel loading time Fan setting Temperature setting Fan indicator led Pump indicator led Reducer indicator led Fuel is over warning Reducer motor jamming Increase Decrease Digital display Reducer button Fan button Fuel feeding button Alarm button On-off button...
ATTENTION !!! Fuel loading and feeding values are in Table 1. Loading and feeding settings belongs to the fuel only which one used in. It is necessary to do new settings when the fuel type is changed SAFETY TERMOSTAT Safety termostat is placed behind the control panel and steps in breakdown of boiler water setting termostat and prevents the increase of boiler water temperature.
7.2 WARNINGS FOR USE Circulation pump will start running when the burning continues and boiler water temperature comes to 35°C. This prevents extra electric consumption and heats boiler immediately so prevents damages from sweat of steam. Prevents sending water, which wasn't heated completely, to the raditaor.
8. CLEANING AND MAINTAINENCE Following instructions should be followed in order to keep boiler working safe and efficient for long time. Quality of the fuel used, would effect the boiler cleaning time, consumption amount of fuel and efficiency of boiler. Nut coal is burned in boiler.
11. TROUBLE SHOOTING Reason Problem Solution Offer Electricity connection can be loosen Check the connection. Tighten the klemens cables. Reductor doesn't work Clean up the shaft bearing Shaft comes from the reductors can There is H4 warning helezon entrance hole be squeezed.
Page 20
12. CARRYING AND TRANSPORT A) PLACING THE BOILER ON VEHICLE *When the boiler places on vehicle, loading should be with crane. *Gates of the wehicle should be opened previously. *Make use of the supporting ring while loading boiler with crane. *Pass the crane buum hook from the supporting ring.