  • Page 1 rev.no:01 05.2018...
  • Page 2: Table Of Contents

    CONTENT 1.SAFETY ..........................3 1.1 SYMBOL KEY ......................3 1.2 SAFETY PRECAUTIONS ....................3 1.3 GENERAL EXPLANATIONS ..................4 2.INTRODUCTION OF THE DEVICE ................5 2.1 APPERANCE AND EXTERNAL DIMENSIONS ............5 2.2 COMPONENTS OF THE BOILER ................6 2.3 CONTROL PANEL ......................7 3. MOUNTING AND INSTALLATION ................8 3.1 ELECTRICAL CONNECTIONS AND SHORT CIRCUIT RELAY ........8 3.2 SHORT CIRCUIT RELAY CONNECTION DIAGRAM ..........8 3.3 OPENING THE BOX ....................9...
  • Page 3 Maktek Boiler will provide you a safe and comfortable life for many years thanks to conscious use. PLEASE keep this manual carefully so that you can apply when necessary.
  • Page 4: Safety

    1. SAFETY 1.1 Symbol Key This symbol expresses the risk of serious personel injury or death unless taking care of & warnings. This symbol expresses the risks which can cause minor injuries or harms to the environmet and goods. 1.2 Safety Precautions Do not open the protective cover of the device.
  • Page 5: General Explanations

    Fire risk results from overheated law profiled cables. 1.3 GENERAL EXPLANATIONS Maktek Electric Boiler provides the heating by central boiler heating system and with radiators connected to the system and provides hot water by heat exchanger. Installation and services must be in accordance with recent standarts and announced directives.
  • Page 6: Components Of The Boiler

    2.2 COMPONENTS OF THE BOILER...
  • Page 7: Control Panel

    2.3 CONTROL PANEL All functions required to run the boiler is done via two buttons on control panel. These functions can be followed on LCD screen. All failure reportings can be seen on screen via specific codes. • 1. P1 KEY This position is where the device is used for hot water usage.
  • Page 8: Mounting And Installation

    Your device will be held out of guarantee if the installation and operation conditions on this manual are complied. 3.1 ELECTRICAL CONNECTIONS AND SHORT-CIRCUIT RELAY Maktek Omega Electrical Boilers with capacities upto 12 kW can operate both with 230V/50 Hz and 380V50Hz. Higher capacities only operate with 380V/50Hz electricity connection.
  • Page 9: Opening The Box

    3.3 OPENING THE BOX Open the box as seen in the above sketch. Place the box on the ground, arrows on the box pointing to the ground. Cut the cords or remove the staples, fold the lids of the box on each side and turn the box upside down.
  • Page 10: Heating And Hot Water System Installation Connections

    3.6 HEATING AND HOT WATER SYSTEM INSTALLATION CONNECTIONS At DHW function, please make sure that the pressure of the city water network on cold water inlet side is not more that 6 Bars. If the network pressure is more than 6 Bars, a pressure regulator must be added.
  • Page 11: Filling Water To The System

    3.8 STARTING UP First time operation of the boiler must be done by authorised Maktek service personel in order to validate the guarantee of the boiler and to ensure the boiler runs efficiently and safely for many years.
  • Page 12: Circulation Pump Pressure Curve

    3.8.3 CIRCULATION PUMP PRESSURE CURVE MAKTEK Omega Boiler Circulation pump has 3 speed options. You can choose the required pump speed according to the resistance of your installation. You can use the below diagram for deciding the pump speed. Water Flow (m 3 / h)
  • Page 13: Features Of Omega Electric Boiler

    4. FEATURES OF OMEGA ELECTRIC BOILER Maktek Omega Boiler uses ONLY electricity as fuel. The device is equipped with many safety functions to provide risk free operation. Operates with 99% efficiency. Eco-friendly, 0 emissions. Due to its quiet operation and lack of connections like chimneys, it can be mounted in living areas easily.
  • Page 14: Technical Table

    5. TECHNICAL TABLE...
  • Page 15: Electricity Connection Diagram

    6.ELECTRICITY CONNECTION DIAGRAM...
  • Page 16: Safety System Of Device

    7. SAFETY SYSTEM OF THE DEVICE MAKTEK OMEGA ELECTRIC BOILER ; has the following safety features in order to ensure the highest level of safety and highest technology. 7.1 RCD DEVICE (SHORT CIRCUIT RELAY) In case of short circuit, the relay shuts off the electricity connection and prevents any possibility of electruction and prevents any harm to people or the device.
  • Page 17: Domestic Hot Water Ntc Sensor

    7.6 DOMESTIC HOT WATER NTC SENSOR When a sensor failure occurs in hot water system, H2 warning code appears on LCD screen. 7.7 CENTRAL HEATING NTC SENSOR When a sensor failure occurs in central heating system.H1 warning code appears on the LCD screen 7.8 HIGH WATER PRESSURE PROTECTION When there is over pressure in the heating system, the 3 bar safety valve discharges water...
  • Page 18: Guarantee Conditions

    9. GUARANTEE CONDITIONS This guarantee stars from the date of the boiler's first operation and continues to the period of time stated in Guarantee Certificate. In order for this guarantee to be valid, first operation and periodical maintenance must be performed by an authorized service in your area.