Figure 12 Overview Risk Assessment - M&C SR Series Instruction Manual

Peristaltic pump
Hide thumbs Also See for SR Series:
Table of Contents

Advertisement

Starting
point
Severity of injury:
S1 = 1 = minor (reversible injury)
S2 = 2 = serious (irreversible injury, death)
Frequency and duration:
F1 = 1 = infrequent or short exposure to hazard
F2 = 2 = frequent (more than once per hour/shift)
Possibility of preventing or limiting the damage
P1 = 1 = possible
P2 = 2 = hardly possible

Figure 12 Overview risk assessment

www.mc-techgroup.com
Risk rank or required
performance level
Aggressive condensate possible
Risk rank group A
Chemical burns due to aggressive media possible!
This applies to all liquids in vessels and in the product.
In general, for electrical and mechanical work on the product, wear personal protective
equipment (PPE) in accordance with the risk assessment.
Caution risk of being crushed by rotating parts
Risk rank - group A
The product contains rotating parts. Do not open covers until the device has been
switched off.
Risk value
Low risk
High risk
SR25 | 1.01.01
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr25.1Sr25.2-gSr25.1/ex

Table of Contents