Electrical Connections; Figure 7 Connection Of The Distribution Voltage - M&C SR Series Instruction Manual

Peristaltic pump
Hide thumbs Also See for SR Series:
Table of Contents

Advertisement

Note
11.2

ELECTRICAL CONNECTIONS

Connect the cables for the power supply as follows:
Power

Figure 7 Connection of the distribution voltage

Danger
Note
14
The tightness of the connections can only be guaranteed if the connection hose has
a straight rim (use a hose cutter).
Aggressive condensate is possible.
Chemical burns caused by aggressive media possible!
Wear protective gloves and protective glasses!
Wear proper protective clothing!
Incorrect system voltage can damage the unit. When establishing connections, check
that the system voltage corresponds with the voltage shown on the type plate!
The supply voltage is only allowed to deviate max. +6% resp. -10% from the indication
on the model type plate.
Attention must be paid to the requirements of IEC364 (DIN VDE 0100) when setting
high-power electrical units with nominal voltages of up to 1000V, together with the
associated standards and stipulations.
SR25 | 1.01.01
Power
www.mc-techgroup.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr25.1Sr25.2-gSr25.1/ex

Table of Contents