Installation and operating manual
14. Troubleshooting
In the event of any malfunctions which are not described, malfunctions which cannot be eliminated or
questions, contact BEKO TECHNOLOGIES customer service, see "1.1 Contact" on page 4.
Symptoms
The level indicator's red marking
is visible.
Water is coming out from the
ventilation opening of the clean
water tank.
Possible cause
1. The filter cartridge cannot
absorb any more oil.
2. The filter cartridge is clogged.
3. The riser duct is clogged.
1. The water outlet hose on the
elbow connector is clogged.
2. The connection to the
wastewater system is clogged.
QWIK-PURE
Measure
Replace the filter cartridge (see
section "9.3.2 Replace filter
cartridges" on page 42).
Replace the filter cartridge (see
section "9.3.2 Replace filter
cartridges" on page 42).
Clean or replace the riser duct
Clean or replace the water outlet
hose.
Check and clean the connection the
wastewater system.
CS
®
61 | 64
Need help?
Do you have a question about the QWIK-PURE CS 400 and is the answer not in the manual?