How It Works - Beko QWIK-PURE CS 400 Installation And Operating Manual

Table of Contents

Advertisement

Installation and operating manual

3.2 How it works

The condensate is fed from the condensate collection line via the condensate inlet [A] into the pressure relief
chamber [1]. In the pressure relief chamber [1], entrained compressed air is separated before the condensate
flows through the connecting pipe [3] into the filter cartridge [10].
The condensate flows through the filter cartridge [10] into the collector [8].
The purified condensate is fed from the collector [8] via the riser duct [9] into the clean water tank [4]. The
purified condensate is fed into the waste water connection via the condensate drain port [B] of the clean
water tank [4] .
If the filter cartridge [10] is saturated with oil, the filter cartridge [10] will need to be replaced (see section
"9.3.2 Replace filter cartridges" on page 42).
A level indicator [12] is integrated into the pressure relief chamber [1]. If the filling level in the pressure relief 
chamber [1] rises as a result of impaired condensate flow (see section "14. Troubleshooting" on page 61),
the level indicator [12] will be pushed up so that the red marking on the level indicator [12] will become
visible.
A
1
3
B
4
9
8
QWIK-PURE
10
CS
®
15 | 64