14. Place the end cap on the filter cartridge and turn 
it clockwise all the way.
15. Remove the cover from the pressure relief
chamber and remove the activated carbon mat
from the vent of the pressure relief chamber.
16. Dispose of the activated carbon mat properly
(see section "13. Disposal" on page 60).
17. Fill the QWIK-PURE
vent.
0 Stop filling it as soon as water comes out 
from the condensate drain.
18. Insert the new activated carbon mat into the
vent of the pressure relief chamber and place the
cover on the pressure relief chamber.
19. Slowly open the condensate feed.
20. Check all hoses and connections for leaks (see
section "9.3.5 Leakage test" on page 49).
CS with tap water via the
®