Installation and operation manual
14. Troubleshooting / FAQ
Error or fault pattern
Poor compressed gas quality
High differential pressure
Condensate in downstream
components
Leakage
Possible causes
Excessive load, load surges
Non-functioning condensate
discharge
Incorrect dimensioning
Filter element installed incorrectly
O-ring has been damaged during
installation
Incorrect dimensioning
Excessive contamination
Filter elements destroyed
Condensate discharge defective or
malfunctioning
Cooling downstream of filtration
section
Ageing seals
Mechanical damage
CLEARPOINT
3eco
coalescing filter
®
Remedy
•
Change operating method
•
Avoid pressure surges
•
Observe the prescribed operating
parameters, particularly during
start-up processes
•
Guarantee regular condensate
discharge
•
Dimension the filter according to
the given operating parameters
and replace if necessary
•
Watch direction of flow /
direction of installation of the
filter element
•
Procure new filter element and
O-ring, proceed with care during
installation
•
Dimension the filter according to
the given operating parameters
and replace by larger one if
necessary
•
Shorten the maintenance interval
for filter element replacement
•
Filtration in stages may be
necessary
•
Change in operating method
•
Filtration in stages may be
necessary
•
Replace float drain or carry out
maintenance on BEKOMAT
•
Drying upstream of filtration
required
•
Replace seals within the context
of maintenance work
•
Send in the filter for repair or
replace by a new one
®
47 | 56