5.4.1

Configuration

Table 5-2 Low-level API Configuration Parameters
Parameter
cfg_flags
adc_rate
tmode_rate
zc_level
apt_div
adc_mv_avg
sync_out
d_out
num_teeth
z_tooth_sz
alarm_src
torque_cfg
ttl_cfg
stall_lvl
dout_div
tppm_timeout
© Copyright 2024
United Electronic Industries, Inc.
The tutorial in this section is intended as a supplement to the example code and
the API reference manual.
To configure a Revision 1 board, populate DQ_VR608_CFG structure using the
DqAdv608SetCfg() function. To configure a Revision 2 board, populate a
DQ_VR608_CFG_R2 structure via DqAdv608SetCfgExt().
DNx-VR-608 configuration parameters apply to either an individual channel (C),
a pair of channels (P), or the entire board/layer (L). The parameters, their
application scope (C/P/L), and supported revision(s) are listed in Table 5-2.
Some parameters take in a single value and some accept a logically grouped
combination of constants. Please refer to the "PowerDNA API Reference
Manual" for a complete description of each parameter.
C/P/L
Rev.1
Rev.2
L
L
C
C
C
P
L
L
C
C
L
P
L
C
L
L
February 2024
DNx-VR-608 Variable Reluctance Interface
Programming with the Low-level API
Description
OR in flags to change associated
parameters
Analog input rate for the board
Rate at which data is stored in Timed Mode
Zero crossing level for ZC_FIXED. If the
desired zero crossing level is 0 V, UEI
recommends setting
slightly above 0 to avoid false positives,
e.g., 0.1 V.
Peak threshold divider for APT_LOGIC
Moving average for ZC_LOGIC and
APT_LOGIC
Output signals on Sync [3:0]
Output signals on DOut [3:0]
Number of teeth on the wheel for RPM
calculation
Number of missing or fused teeth
Configure open circuit, stalled rotation, and
overspeed alarms. Open circuit alarms do
not apply to TTL inputs.
Torque sensor polarity and rotation direction
Route DIn[3:0] to internal counters
Set noise floor level for the stall alarm. The
value is a point on the input range. Input
values below this point are ignored
Configure dividers on digital outputs
Set TPPM timeout in 10 ms increments
Chapter 5
zc_level
to a value
www.ueidaq.com
508.921.4600
45