Control Panel - Beretta POWER EVO-X Series Installation Manual

Condensing high power boiler
Table of Contents

Advertisement

Control panel

1.9
A
A
+
B B
1
1
Normally used to increase the DHW temperature
A
value, but when the arrow
confirmation button
Normally used to decrease the DHW temperature
B
value, but when the arrow
back/annul button
Normally used to increase the heating water
C
temperature value, but when the arrow
highlighted it allows you to navigate menu P1
Normally used to decrease the heating water
D
temperature value, but when the arrow
highlighted it allows you to navigate menu P1
Access to the clock setting menu (see paragraph "3.2
A+C
Programming the boiler")
Used to modify the boiler operating status (OFF,
1
SUMMER and WINTER)
2
Used to reset the alarm status, or to interrupt the
venting cycle
Used to access the INFO menus and menu P1.
Enter
3
When the
has an ENTER function and is used to confirm the value
set while programming a technical parameter
1+3
Button lock and release
Used when the boiler is OFF, to activate the flue gas
2+3
analysis function (CO)
b
The DHW function is only shown on the display in cases B and C - see paragraph "1.1 Boiler description"
The control panel acts as a machine interface, displaying the system settings and providing access to the parameters.
The configuration MENU is organised with a multi-level tree structure. An access level has been fixed for each sub-menu: USER level
always available; TECHNICAL level protected by means of a password.
Below is a summary of the SETTINGS MENU tree structure.
+
RESET
MENU
2
2
3
3
is highlighted it acts as a
is highlighted it acts as a
icon appears on the display, this button
Indicates the connection to a remote device (OT or
RS485)
C C
lndicates the connection to a wi-fi device
Indicates the presence of an outdoor temperature
D D
sensor
Indicates the activation of special DHW functions,
or the presence of a solar thermal management
system
Lights up if an alarm is triggered
Lights up along with the icon
fault (apart from flame and water alarms)
Indicates the presence of a flame (
of a flame lockout)
Lights up for alarms requiring a manual reset by the
Reset
operator
Enter
Lights up when confirmation is required
When this icon is active, the "confirm" function of
is
button A is active
When this icon is active, the "back/annul" function of
button B is active
is
When this icon is active, the user can navigate the
menu or increase the value of the selected parameter
When this icon is active, the user can navigate
the menu or decrease the value of the selected
parameter
Lights up if heating mode is active; flashes with a
heating request in progress
Lights up if DHW mode is active; flashes with a
DHW request in progress
Indicate the setpoint defined (1 notch=minimum
value, 4 notches=maximum value)
Indicate the days of the week
1 2 3 4 5 6 7
AUTO
NOT AVAILABLE ON THIS MODEL
ON
MAN ON
NOT AVAILABLE ON THIS MODEL
MAN OFF NOT AVAILABLE ON THIS MODEL
14
in the event of a
in the event

Advertisement

Table of Contents
loading