Table 3: Error messages
Datei:BA_EcoStar545D-M_9662798_EN_2009-05.doc
MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
ERR.-No. Description
301
Number of final rinse cycles for
tank filling exceeded
Tank level analysis disrupted
302
During the self-cleaning pro-
gramme the tank level (S3) does
not fall on time.
(Only with built -in drain pump.)
304
Tank temperature not reached
after max. heat time (P.314)
310
Temperature sensor short circuit
311
Temperature sensor interruption
312
Actual Tank temperature too high
(>85°C)
Should information or fault numbers not shown in the tables be indicated, or
should the suggested measure not lead to the elimination of the fault, please no-
tify a customer service technician.
W e reserv e the right to change execution and construction!
Possible cause
Feeding water pressure too low
Sieve in feeding valve is dirty
Rinse jets soiled
Air trap soiled
Condensate in level pipe
Hose kinked / loose / not watertight
Fresh water supply insufficient
(water faucet closed)
Drain pump soiled / defective
Rotor loose
Drain pump plug connector loose
Start capacitor defective
Tank level analysis disrupted
No signal from ON/OFF circuit boards
Tank heating defective / thermal fuse
Radiator
Temperature sensor defective, incorrect
installation position
Tank protection defective, performance
switch loose
See 210
See 211
See 212