Meiko FV 28 G-M Operating Instructions Manual page 33

Table of Contents

Advertisement

Operating instructions EcoStar 545 D-M
Par.
Configuration
No.
options
225
Power supply
mode
detergent dosing
pump
228
Water softener
EW 10 incorpo-
rated?
240
Detergent pump
activation mode
241
Air gap (FA) in-
corporated?
242
Drain pump (LP)
incorporated?
243
Frost drainage
(without FA)
321
Rinse agent pump
output
322
Detergent pump
output
326
Pipe vent time
Rinse agent
327
Pipe vent time
Detergent
346
Indication
LED 2 or LED 1
347
Desinfection
temperature
348
Desinfection
temperature
Datei:BA_EcoStar545D-M_9662798_EN_2009-05.doc
MEIKO Maschinenbau GmbH & Co. KG, Englerstr. 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
Use as
value
range
Parameters
0 ...4
Parameters
0/1
Parameters
0/1
Parameters
0/1
Parameters
0/1
Parameters
0/1
Parameters
0.1 ...10
Parameters
0.1 ...20
Parameters
0 ...255
Parameters
0 ...100
Parameters
0/1
Parameters
10 ...80
Parameters
0 ...90
W e reserv e the right to change execution and construction!
Unit
Factory
setting
-
1
Definition: Energizing detergent
pump:
0 – No signal
1 – Energizing according to calcu-
lated running time
2 - Energizing as final rinse
3 - Energize as wash pump
4 – Option – detergent pump using
negative pressure dosing ADT
-
0 or 1
In case of incorporated water sof-
tener set to 1
-
0
Effective only upon power supply
reset ON/OFF
ATTENTION! All changes to ser-
vice parameters will be
reversed.
Power supply reset must be car-
ried out within 5 minutes, otherwise
factory settings will not be loaded.
Without power supply reset, the
information 123 will be displayed.
-
0
0: FA not available, final rinse over
Y1
1: FA available, Plug connector
-
0
0: LP not incorporated
1: LP incorporated
-
0
0: No effect
Tank filling before Heating
l/h
1.3
Rinse agent pump.
Output definition.
l/h
8.5
Detergent pump
Output definition.
sec.
180
Activate rinse agent pump tempo-
rarily to remove air from pipe.
sec.
30
Activate detergent pump tempo-
rarily to remove air from pipe.
-
1
0: LED2 with LEDs
1: LED1 with temperature display
°C
0
Only with disinfection machine no.4
in parameter 201
10 sec.
0
Only with disinfection machine no.4
in parameter 201
Note
33/44
9662798

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents