Allen-Bradley 160-RS1 User Manual page 27

Serial communication module
Table of Contents

Advertisement

Parameter Number
Drive
RS1
Access
(N10:, N30:)
(N13:, N33:)
130
30
Read
131
31
Read
132
32
Read
133
33
Read/Write [Logic Mask]
[Parameter Name] and Description
[DIP Switches]
Displays the current DIP switch settings.
Bit
3
2
1
0
Description
0
0
9600 (Default)
0
1
2400
1
0
1200
1
1
EPROM Mode
0
DF1 Point-to-Point (Default) SW3
1
DF1 Multi-Drop
0
BCC (Default)
1
CRC
[Actual Speed]
Returns speed feedback from the drive. This is the actual drive speed
scaled from 0 to 32767, where 0 = 0 Hz and 32767 = P33 - [Maximum
Frequency].
[Logic Status]
Returns logic status (N41:0). Refer to page 5–3 for data format.
This parameter determines the source of the drive control logic.
A value of "1" corresponds to terminal block control, and any drive input
mode (P46 - [Input Mode]) value except "2" or "6."
A value of "2" corresponds to RS1 Module logic control. The input mode
value is "2" or "6."
If the Logic Mask value is changed from "1" to "2," the terminal block logic
control is masked out by the RS1 Module. The module does this by
changing the Input Mode to the last previously active network mode, "2" or
"6" (if a network mode has not been active since drive power was applied,
it is set to "2").
If the Logic Mask value is changed from "2" to "1," the RS1 logic control is
masked out by the RS1 Module. The module does this by changing the
Input Mode to the last previously active non-network mode (if a non-
network mode has not been active since drive power was applied, it is set
to "0").
IMPORTANT: Power must be cycled or P56-[Reset Functions] must be
set to "2" for this change to take affect.
Parameter Descriptions
Min./Max.
Values
0 to 0xF
0 to 15
Switch
SW1,
SW2
SW4
0 to 32767
0 to 65535
1 to 2
6–3
Default
0000
0
0
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

5735886