ETC Installation Guide
Relay Controller
RDM Parameters
You can set the following RDM parameters on the Relay Controller using
Concert or another RDM controller.
Parameter
E120_DEVICE_LABEL
Device Label
0x0082
DMX Start
E120_DMX_START_ADDRESS
Address
0x00F0
DMX
E120_DMX_PERSONALITY
Personality
0x00E0
DMX Fail
E137_1_DMX_FAIL_MODE
Mode
0x0141
(Data Loss)
ETC_E120_PACKET_DELAY
Packet Delay
0xB000
Relay Controller
ID and Number
Page 14 of 16
Description
User-configurable name
for the device
DMX address,
range = 1–512
Sets the channel mode:
• Dual-channel mode
• Single-channel mode
Configures the behavior
when DMX is lost:
• Go to Full
• Hold Last Look
• Wait and Fade
Requires any change of
level to be present for at
least this number of
packets before action is
taken (open/close the
relay or change 0–10 V
output). Range = 0–50.
Default Value
ETC DMX Dual Relay
1
Dual-channel mode
Go to Full
0
ETC
Need help?
Do you have a question about the Unison Foundry Relay Controller and is the answer not in the manual?