2.5. 7500-Man-MV-01 Manual Manifold
The 7500-MAN-MV-01 combines in one device a ball valve for purging and a needle
valve for pressurizing an enclosure. The ball valve has a handle for easy actuation.
To provide security and prevent tampering, the needle valve requires a slot-head
screwdriver to set the enclosure pressure.
Note
The 7500-MAN-MV-01 manifold can be used with 7500 series or 5500 series purge and
pressurization systems.
2.5.1
Technical Data: 7500-Man-MV-01
Property
General specifications
Equipment architecture
Series
Hazardous enviroment
Pneumatic parameters
Protective gas supply
Pressure requirement
Purge flow rate
Connections
Value
max. enclosure size 450 ft³ (12.7m³)
7500
gas or dust
compressed air or inert gas, 40 μm filter, free from oil
10...120 psig (0.7...8.2 bar)
Pressurization valve: Cv (flow coefficient) = 0.4
Purging valve: Cv (flow coefficient) = 1.4
inlet/outlet: 1/2 inch NPTF