Technical Data: 7500 Manifolds
Property
General specifications
Operation mode
Series
Hazardous environment
Supply
Rated voltage
Power consumption
Pneumatic parameters
Protective gas supply
Pressure requirement
Purge flow rate
Connections
ambient conditions
Ambient temperature
Temperature class T4/130° C
Temperature class T6/180° C
Storage temperature
Mechanical specifications
Connection type
Degree of protection
Material
Hazardous location approvals
EU-type examination certificate
(marking)
IECEx approval
38
d
roducT
eScriPTion
Value
For automatic purging
7500
gas or dust
230 VAC ± 10%
115 VAC ± 10%
24 VDC ± 10%
230 VAC @ 1.8 W
115 VAC @ 9 W
24 VDC @ 9 W
instrument grade air or inert gas
T6 version: 0.2 bar (2.9 psi) to 4.0 bar (58 psi)
T4 version: 0.2 bar (2.9 psi) to 16 bar (232 psi)
Kv value water 3.8 m³/h
G1/2 (13 mm)
-40 °C ... +55 °C (-40 °F ... 131 °F)
-40 °C ... +50 °C (-40 °F ... 122 °F)
-40 °C ... +80 °C (-40 °F ... 176 °F)
Inlet/outlet size: G1/2 (13 mm)
Jet size: 3.0 mm and 4.5 mm (included)
IP65
Body: brass
Valve (internal): brass, stainless steel, and plastic
Seal: NBR
II 2 G Ex mb IIC T4/T6 Gb
II 2 D Ex mb tb IIIC T130 °C/T6 Db
Protection by encapsulation
Ex mb IIC T4/T6 Gb
Ex mb IIIC T130 °C/T80 °C Db