2.6.1
Technical Data: 5500 Manifolds
Property
General specifications
Operation mode
Series
Hazardous environment
Supply
Rated power equipment
24 V DC
120 V DC
230 V DC
Rated power equipment
24 V DC
120 V DC
230 V DC
Rated power equipment
24 V DC
120 V DC
230 V DC
Voltage tolerance
Fuse rating
DC voltage
AC voltage
Pneumatic Parameters
Protective gas supply
Pressure requirement
Purge flow rate (solenoid valves)
Pressurization flow (needle valve)
Pneumatic Parameters
Protective gas supply
Pressure requirement
Purge flow rate (solenoid valves)
Pressurization flow (needle valve)
Pneumatic Parameters
Protective gas supply
Pressure requirement
7500 S
Value
For automatic purging
5500 and 7500
gas or dust
5500-MAN-CDUL
5.6 W
7.2 VA, 60 Hz
7.2 VA, 60 Hz
5500-MAN-CD01
4.6 W
6.8 VA, 60 Hz
6.8 VA 60 Hz
5500-MAN-EX01
2.6 W
3.1 VA, 50...60 Hz
3.0 VA, 50...60 Hz
± 10%
500 mA
80 mA
5500-Man-CDUL (only 60 Hz for aC version)
40 μm filtered air or inert gas
20 psi (1.4 bar) to 120 psi (8.2 bar)
Cv (flow coefficient) = 1.4
Cv (flow coefficient) = 0.24
5500-Man-CD01
40 μm filtered air or inert gas
20 psi (1.4 bar) to 120 psi (8.2 bar)
Cv (flow coefficient) = 1.4
Cv (flow coefficient) = 0.24
5500-Man-EX01
40 μm filtered air or inert gas
25 psi (1.7 bar) to 115 psi (8.0 bar)
M
P
erieS
anual
roducT
d
eScriPTion