Pepperl+Fuchs 7500 User Manual page 34

Purge system
Hide thumbs Also See for 7500:
Table of Contents

Advertisement

7500 S
M
 P
erieS
anual
Purge flow rate (solenoid valves)
Pressurization flow (needle valve)
Mechanical Specifications
Degree of protection (connector)
Mass
Dimensions
Mounting Manifold
Mounting hole
Material
Housing
3/8 inch compression fittings
Pressure ports
Bulkhead fitting
Mounting bolts
Sealing washers
Pneumatic connection type
Input port
Output port
Electrical Connection
5500-MAN-CD
5500-MAN-EX01
Hazardous Location approvals
UL approval
CSA approval
Temperature Class
Hazardous Location approvals
FM approval
CSA approval
Hazardous Location approvals
EU-type examination certificate
(marking)
34
d
roducT
eScriPTion
Cv (flow coefficient) = 1.4
Cv (flow coefficient) = 0.24
Type 7 and 9
1250 g (2.8 lb)
See dimension drawings.
5500-Man-CDUL / 5500-Man-EX01 / 5500-Man-CD01
17/64" (6.75 mm) Screws, nuts, and sealing washers
Anodized aluminum
AISI 316L (1.4404) stainless steel
3/8 inch NPTF
AISI 316L (1.4404) stainless steel
¼-20, 316 stainless steel
Pneumatic
3/8 inch tube compression fitting
3/8 inch tube compression fitting
1/2" NPTF thread connection with 24 inch (0.61 m) flying leads
3 m cable
5500-Man-CDUL
Class I Division 2, Group A–D
Class II Division 2, Group F+G
Class I Division 2, Group A–D
Class II Division 2, Group F+G
T3C
5500-Man-CD01
Explosionproof: Class I Division 1, Group A–D, T4
DIP: Class II Division 1, Groups F+G, T4
Nonincendive: Class I Division 2, Groups A–D, T4
Suitable for Class II Division 2, Groups F+G, T4
Class I Division 1, Groups A–D; Class II, Groups E, F, G
Class I Division 2, Groups A–D
5500-Man-EX01
II 2 G Ex mb IIC T5 Gb
II 2 D Ex mb tb IIIC T95 °C Db IP65
Protection by encapsulation

Advertisement

Table of Contents
loading

This manual is also suitable for:

Epv-75007500-man-mv-017500-mtd-pmsw-01

Table of Contents