Kemp kti ETS-LS06 User Manual page 64

Ets torque monitoring electric screwdriver
Table of Contents

Advertisement

the torque tester.
Displayed Torque Offset Setting
11. System Lock Settings
When any errors occur during fastening, the user can choose to lock the system to
avoid further use of the tool. Click Yes to activate system lock and choose from the
following six conditions of which the system should be locked. Click no to skip this
setting. Please note that between "time" and "turn" method of detection, the user can
only choose one for the system lock.
12. Advanced System Lock Settings
The user can choose to deactivate the system lock through I/O or external scanners,
press no to skip the setting. This function is useful when a scanner is used on the work
piece before fastening process begins (if the scanner detects a wrong work piece on
the assembly line), or an I/O signal is sent from an automation system to begin
fastening
System Lock Settings
64

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kti ets-ls16Kti ets-ls20Kti ets-ls24

Table of Contents