Setting Parameters - Kemp kti ETS-LS06 User Manual

Ets torque monitoring electric screwdriver
Table of Contents

Advertisement

4.1.5. Setting Parameters

This section explains how each parameter is set up in details. All settings in each page
will be saved once "next page" button is pressed.
1. Torque Related Parameters
A. Target Torque: The target fastening torque
B. Maximum Torque: The upper limit of the torque specification. For example:
if the target torque is 1Nm and the required accuracy is ±10%, the upper limit
should be 1.1Nm
C. Minimum Torque: The lower limit of the torque specification. For example:
if the target torque is 1Nm and the accuracy is ±10%, the lower limit should
be 0.9Nm
Press on the numerical value to activate keypad
Torque Related Parameters
28