6. Screw Counter
When the screw counter is activated (press Yes), and when error occurs during the
fastening process, a lock on the system will be activated, and the lock needs to be
deactivated before continuing.
Number of Screws and Screw Counter Lock
7. RPM Setting
The fastening speed or RPM can be adjusted from 200rpm to 1000rpm. Press on the
numerical value to activate keypad.
8. Screw Seating Stability Control
Press YES to activate seating stability control, this function will stabilize the fastening
process right before the seating of the screw to enhance fastening torque accuracy.
When this function is activated, the screwdriver will slow down (rpm) when it reaches
either the minimum turns or the minimum time, depending on which mode the user
has selected (please refer to the previous pages for detection method). Please note that
the stability control should be activated only when the target torque is lower or equal
to 80% of the highest torque setting on the tool, if the target torque exceeds 80% of
the highest torque value the clutch might not perform properly. Please note that if the
user activates the stability control, torque calibration must also be done with the
stability control turned on, in order to attain the optimal consistency of torque
detection. The result of the calibration varies between activation and
deactivation of the stability control due to the difference in speed during
fastening (slow and high speed).